EasyManua.ls Logo

Faber JELLING - Restrictor Table (100;150)

Faber JELLING
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
> > > > 12
UK
IRL
Appendix A: Example calculation
Calculation 1:
Calculating horizontal extension fig. 2a:
Flue length C + E = 1m + 1m 2 m
Elbows D = 2m 2 m
Total horizontal extension 4 m
Measure or calculate effective height (Hvert)
Flue length A 1 m
Roof mounted terminal 1 m
Total effective height 2 m
Calculation 2:
Calculation horizontal extension fig. 2b:
Flue length J + L = 0,5 + 0,5 1 m
Elbows K + M = 2m + 2m 4 m
Terminal 1 m
Total horizontal extension 6 m
Calculation effective height (Hvert)
Flue length H 1 m
Always check if the calculated situation is allowed (see Appendix B: Flue restrictor)