13 < < < <
UK IRL
Appendix B: Flue restrictor
Determining of the right flue restrictor:
Calculate the total horizontal- and vertical length of the flue, according to the
calculations displayed above
Determine according to the table the right flue restrictor size
When meeting an X, and when the values are outside the table, the combination is
not allowed
Normally the 30 mm flue restrictor is preinstalled
Horizontal length (m)
Jelling
0
1
2
3
4
5
6
0 X
X
X
X
X
X
X
0,5 X
X
X
X
X
X
X
1 30 0
0
X
X
X
X
1,5 30
30
0
0
0
X
X
2 30
30
30
0
0
0
0
3 40
30
30
30
0
0
0
4 40
40
30
30
30
0
0
5 50
40
40
30
30
30
0
6 50
50
40
40
30
30
30
7 60
50
50
40
40
30
X
8 60
60
50
50
40
X
X
9 60
60
60
50
X
X
X
10 65
60
60
X
X
X
X
11 65
65
X
X
X
X
X
Total effective height (m)
12 65
X
X
X
X
X
X