EasyManuals Logo

Faber JELLING Installation Guide

Faber JELLING
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
> > > > 14
UK
IRL
Appendix C : Technical specifications
Country UK /
IRL
UK / IRL
UK / IRL
Cat
Appliance type C11 /
C31
C11 /
C31
C11 / C31
Reference gas G20
G30
G31
Input (Nett) kW
6.5
6.5
6.5
Efficiency class 2
2
2
Inlet pressure mbar
20
30
37
Gas rate (15º C / 1013 mbar) l/h
690
200
255
gram/h
500
480
Working pressure mbar
10.0
22.0
24.5
Injector size mm
3x1.50
3x0.9
3x0.9
Reduced input restraint
mm
1.6
0.85
0.85
Pilot assembly SIT160
SIT160
SIT160
Code Nr 51
Nr 30
Nr 30
Flue size mm
Ø 100-150
Ø 100-150
Ø 100-150
Std. Flue restrictor mm
30
30
30
Gas control GV36 GV36
GV36
Connection
Nut/olive
8 mm
8 mm
8 mm