23
Defines the operating logic of the start (I3) contact.
Closed (Def.): enables the adjuster (start) with the contact closed;
Open: enables the adjuster (start) with the contact open;
Enabling of the kick start. This parameter is set for loads that need a torque start to
move at low speeds.
ON (Def.): function enabled OFF: function disabled
Factory settings reset: reset to standard parameters (except for the operating time of
the adjuster).
Caution: once entered the reset control through the key , the old settings will be
lost and the controller will be reset accoriding to the pre-setting MP420_50.
MOTOR SETTINGS
Allows to set manually the cos-phi of the load to enhance its adjusting.
Min. 0.1 Max. 1 Def. 0.8
Allows to enable a function that automatically detects the value of the cos-phi of the
motor and save it in the parameter COS-PHI (available only on demand).
Caution: the controller will be restart and the output voltage will be increased gradually
up to the 100% to return to the basic setting value. The whole process will be automatic
and last few seconds.
Minimum adjustable voltage, used to limit the load minimum speed.
Min. 15 % Max. Max.Lim. Def. 15%
Maximum adjustable voltage, used to limit the load maximum speed.
Min. Min.Lim. Max. 100% Def. 100%
Time employed by the adjuster to go from 0% to 100% of the output signal 0-10V.
Min. 2 sec Max. 60sec Def. 5 sec.
Defines the enabling of the jump window specified in the parameters Sup.Min.Lim.1
and Sup.Max.Lim.1 of the adjuster. It is enabled to prevent events of mechanical
resonance. Def. OFF
Caution: this is a prioritary function on any operating cycle.
Lower voltage of the jump window.
Min. 0% Max. Sup.Max.Lim.1 Def. 20%
(this parameter is visualized only if “Suppress.1” is ON).
closed
START CON.
[IB]
*
Press ENT
RESET ?
[IB]
*
15
MIN. LIMIT
[IM]
%
100
MAX. LIMIT
[IM]
%
5
RAMP
[IM]
sec
off
SUPPRESS.1
[IM]
*
20
SUP.MIN.LIM.
1
[IM]
%
OFF
KICK START
[BS]
*
0.8
COS
-
PHI
[ES]
OFF
CosPhi auto?