171
EnglishEnglish
MALFUN.
CODE
51
53
58
59
66
98
99
VERIFICATIONS and SOLUTIONS
POSSIBLE CAUSESDESCRIPTION
Pressure sensor signal out of
range
Autosteam thermocouple signal
out of range
Boiler overpressure alarm
(only for machines with a pressure
sensor)
Boiler: Refill timeout
- 15 minutes
Irregular dose coffee cycle
Historical malfunctions and
wash 1 reset
Default data input
Sensor failure
Card failure
Thermocuple
disconnected
Wrong configuration
during standard data
insertion
Level probe failure; boiler
overfilled.
Resistance always
powered.
No water
Refill EV failure
Wiring interrupted
Card failure
No water
Flowmeter failure
Water circuit blocked
Wiring interrupted/
grounded
Breakdown log
initialization.
Check cabling
Replace the sensor
Replace the card
• Enter in the programming mode and insert the correct
standard data..
• Check connections.
• Replace Turbosteam probe.
Check cabling
• Check water is supplied from the main line.
• Check there are no fitting obstructions or leakage.
• Check flowmeter electrical connections.
• Replace the broken flowmeter.
• Replace the broken board.