INSTALLATION
CAUTION!
Hobs supplied by the manufacturer are tted
with burners designed for the gas specied on
the nameplate and in the warranty.
Nameplate is located on the bottom of the
housing and lists information on the type of
gas the appliance is intended for.
In order to adapt the hob to another gas type:
• replace the nozzles (see table),
• adjust the valves for a reduced ow.
Adapt the hob to a particular
type of gas
This may be performed by an installer with the
appropriate qualications only.
If the gas, which the hob will be supplied with
is dierent from the gas type specied by the
manufacturer, i.e. G20 (2H) 20 mbar, replace
the burner nozzles and adjust the ame.