WATERINSTALLATION
Waterinstallationiscarriedoutasshowninfigures3and4.Thehotwaterlinetothedishwashermust
providebetween25
±5
psiofwaterpressure.Thehotwaterheatershouldbesettodeliver140F(notlower
than120°F)watertemperaturetothedishwasherforbestresults.Use¾”coppertubinginletline.
CAUTION:Donotconfusestaticpressurewithflowpressure.Staticpressureistheline
pressureina“no
flow”condition(allvalvesandservicesareclosed).Flowpressureisthepressureinthefilllinewhenthe
solenoidvalveisopenedduringthecycle
THEDISPLAYOFTHEPRESSUREGAUGESHALLBECLEARLYVISIBLEOFTHEOPERATOROFTHEMACHINE.THE
GAUGESHALLHAVE
INCREMENTSOF1psi(7kpa)ORSMALLERANDSHALLBEACCURATETO±2psi(±14kpa)IN
THE20psi(103‐172kpa)RANGES.IFTHEGAUGEISLOCATEDUPSTREAMOFTHECONTROLVALVE,ITSHALLBE
MOUNTEDINANACCESSIBLEVALVEWITHA¼INIRONPIPESIZE
CONNECTION.
Ifthewaterpressureislessthan20psi(1.4kg/cm
2
),installationofawaterpumpisrequiredasshowninFig.
4.Inareaswherethepressurefluctuatesorisgreaterthantherecommendedpressure,itissuggestedthata
waterpressureregulatorbeinstalled.
S=Gatevalve
F=Filter
H=Hose
E=Fillvalve
M=Pressuregauge
R=¾”Co
er
S=Stopcock
F=Filter
H=Hose
E=Electrovalve
B=Electropump
M=Manometer
R=¾”Co
er