E14 BLOWER Q1 (only AG)
Chamber ignition control
blocked. This occurs after
3 failed ignition attempts.
The oven is completely disabled.
E15 FAULT Q1 (only AG)
- Fault in the chamber
ignition control.
- SV gas is not activated.
- Not possible to unlock
ignition control.
The oven is completely disabled.
E16 BLOWER Q2 (only AG) Steam blower error.
It is only possible to operate in
Convection mode.
E17 BLOWER Q2 (only AG)
Steam ignition control
blocked. This error occurs
after 3 failed ignition
attempts.
It is only possible to operate in
Convection mode.
E18 FAULT Q2 (only AG)
- Fault in the steam.
ignition control.
- SV gas is not activated.
- Not reached.
It is only possible to operate in
Convection mode.
22 CONTROL TEMP
The NTC of controller
exceeds 70 ºC.
The oven is completely disabled.
E23 FLUEPIPE Faulty flue pipe motor. The oven is completely disabled.
24 CHAM. CONNEX
Communication error. The
chamber card does not
respond.
The oven is completely disabled.
25 PMD CONNEX
Communication error. The
control holder card does
not respond.
The oven is completely disabled.
26 VAP CONNEX
Communication error. The
steam card does not
respond.
It is only possible to operate in
Convection mode.
E27 BMF CONEX GAS
Communication error. The
gas card does not
respond.
The oven is completely disabled.

Table of Contents

Other manuals for Fagor AE-101

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor AE-101 and is the answer not in the manual?

Fagor AE-101 Specifications

General IconGeneral
BrandFagor
ModelAE-101
CategoryOven
LanguageEnglish

Related product manuals