SERVICE MANUAL
ADVANCE OVENS
04/02/2020 143
It is only possible to operate in Convection mode
“E6 CALIBRATION”
DESCRIPTION
It was not possible to calibrate in 15 minutes.
CONSEQUENCE
The oven continues to function normally.
“E7 ERROR AE” (disabled)
DESCRIPTION
- AE inlet does not work
- The connection has been cut off
- The motor does not start within 10 seconds of a start request.
- Does not exceed 500 rpm within 20 seconds of a start request.
CONSEQUENCE
The oven is completely disabled..
“E8 WATER REQUIRED”
DESCRIPTION
VDV has been running for 7 or more minutes and the maximum level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
“E9 DRAIN ERROR”
DESCRIPTION
VAC has been running for 1 or more minutes and level does not fall below minimum.
CONSEQUENCE
It is only possible to operate in Convection mode
“E10 CV FAULT”
DESCRIPTION
With TG < 80 ºC, when CV operates, and in 10 minutes TG does not rise more than 3 ºC.
CONSEQUENCE
It is only possible to operate in Convection mode
“E11 CC FAULT”
DESCRIPTION
The CC operates and in 25 minutes, TC does not increase 3 ºC or more provided TC < (setting
–10 ºC).
CONSEQUENCE
The oven is completely disabled.
“E12 CONTROL TEMP”
DESCRIPTION
NTC of controller reaches 60 ºC, but does not exceed 70 ºC.
CONSEQUENCE
The oven continues to function normally.
“E13 BLOWER Q1” (Only gas ovens)
DESCRIPTION
Chamber blower error.
CONSEQUENCE
The oven is completely disabled.
“E14 BLOWER Q1” (Only gas ovens)
DESCRIPTION
Chamber ignition control blocked. This occurs after three failed ignition attempts.