Drive modules
DRIVE MODULES
Modular drives
3.
103
DDS
HARDWARE
Ref.1310
F. H3/12
Current derating on “AXD/MMC 2.75” drives for fc = 4 kHz.
F. H3/13
Current derating on “AXD/MMC 3.100” drives for fc = 4 kHz.
F. H3/14
Current derating on “AXD/MMC 3.150” drives for fc = 4 kHz.
F. H3/15
Current derating on “MMC 3.200” drives for fc = 4 kHz.
35 40 55 60
40
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
50
In
60
Imax
70
30
20
AXD/MMC 2.75
T ambient In Imax
° C °F Arms Arms
35 95 37.5 75.0
40 104 37.5 75.0
45 113 37.5 75.0
50 122 32.2 64.4
55 131 26.6 53.3
60 140 20.7 41.3
35 40 55 60
40
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
60
In
80
Imax
20
100
AXD/MMC 3.100
T ambient In Imax
° C °F Arms Arms
35 95 50.0 100.0
40 104 50.0 100.0
45 113 50.0 100.0
50 122 45.8 91.7
55 131 41.3 82.7
60 140 36.7 73.3
35 40 55 60
60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
80
In
100
Imax
40
120
140
160
AXD/MMC 3.150
T ambient In Imax
° C °F Arms Arms
35 95 75.0 150.0
40 104 75.0 150.0
45 113 75.0 150.0
50 122 70.6 141.3
55 131 65.6 131.3
60 140 60.5 121.0
MMC 3.200
T ambient In Imax
°C °F Arms Arms
35 95 90.0 180.0
40 104 90.0 180.0
45 113 90.0 180.0
50 122 84.3 168.7
55 131 78.0 156.1
60 140 71.5 143.1
35 40 55 60
100
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
In
150
50
200
Imax