Drive modules
DRIVE MODULES
Modular drives
3.
105
DDS
HARDWARE
Ref.1310
F. H3/21
Current derating on “AXD/MMC 2.75” drives for fc = 8 kHz.
F. H3/22
Current derating on “AXD/MMC 3.100” drives for fc = 8 kHz.
F. H3/23
Current derating on “AXD/MMC 3.150” drives for fc = 8 kHz.
F. H3/24
Current derating on “MMC 3.200” drives for fc = 8 kHz.
AXD/MMC 2.75
T ambient In Imax
° C °F Arms Arms
35 95 37.5 75.0
40 104 37.5 75.0
45 113 37.1 74.2
50 122 33.3 66.5
55 131 29.3 58.6
60 140 25.2 50.4
35 40 55 60
40
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
50
In
60
Imax
70
30
80
35 40 55 60
40
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
60
In
80
Imax
20
100
0
AXD/MMC 3.100
T ambient In Imax
° C °F Arms Arms
35 95 50.0 100.0
40 104 50.0 100.0
45 113 50.0 100.0
50 122 42.7 85.4
55 131 35.2 70.3
60 140 27.3 54.5
AXD/MMC 3.150
T ambient In Imax
° C °F Arms Arms
35 95 75.0 150.0
40 104 75.0 150.0
45 113 75.0 150.0
50 122 67.9 135.6
55 131 60.6 121.2
60 140 53.1 106.2
35 40 55 60
60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
80
In
100
Imax
40
120
0
140
160
35 40 55 60
100
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
In
150
50
200
Imax
MMC 3.200
T ambient In Imax
°C °F Arms Arms
35 95 90.0 180.0
40 104 90.0 180.0
45 113 90.0 180.0
50 122 86.1 172.2
55 131 81.2 162.4
60 140 76.2 152.4