FagronLab™ BASIC – User Manual | 26
FagronLab™ BASIC
Emulsion+
With the mixing parameters "Emulsion+" liquid components can be incorporated into a melted foundation and cooling down
parameters.
As an example, the preparation containing emulsific. aquosa, lannette or cera.
To ensure a homogenous distribution we recommend applying disp. blades for jar sizes up to 200 ml and the standard mixing
blades for larger batches.
The jar is heat resistant up to 85°C/185°F and can be used in a hot-water bath or microwave. The melting components can be
melted directly in the jar.
If there is no water in the formulation, the components can be melted directly in the jar on a hot-water bath. Formulation
containing an aqueous phase can be melted in a hot-water bath or the microwave, leave the regular nozzle open and set the
microwave to a low power setting. The temperature control with a thermometer should take place in short intervals to make sure
the compound is not overheating.
To support the cool down process with the FagronLab™ BASIC a cooling cu can be used around the jar and the mixing process for
larger jar sizes can be repeated.
Step 1: combining phase - Level 1 (600 rpm)
Jar size 15 - 30 ml 50 - 100 ml 200 ml 300 - 500 ml
Time (min.) 0:30 0:30 0:30 1:00
Stirrer Disp. Blade Disp. Blade Disp. Blade SMB
Step 3: cool down phase - Level 1 (600 rpm)
Jar size 15 - 30 ml 50 - 100 ml 200 ml 300 - 500 ml
Time (min.) 10:00 10:00 10:00 10:00
Use Cool down phase and emulsions phase alternativ until compound reaches room temperature.
Step 2: emulsions phase - Level 7 (1900 rpm)
Jar size 15 - 30 ml 50 - 100 ml 200 ml 300 - 500 ml
Time (min.) 1:00 1:00 1:00 2:00
Tab: Mixing parameter Emulsion +