2.2.2. Heat pump installation.
The frame must be fixed by bolts (M10) to concrete foundation or brackets. The
concrete foundation must be solid; the bracket must be strong enough and anti-rust
treated;
The heat pump needs a water pump (Supplied by the user). The recommended pump
specification-flux: refer to Technical Parameter, Max. lift ≥10m
When the heat pump is running, there will be condensation water discharged from the
bottom, please pay attention to it. Please insert the drainage tube(accessory) into the
hole and clip it well, then connect a pipe to drain off the condensation water.
2.2.3. Wiring & protecting devices and cable specification
Connect to appropriate power supply, the voltage should comply with the rated voltage
of the products.
Well earth the heat pump.
Wiring must be connected by a professional technician according to the circuit diagram.
Set breaker or fuse according to the local code (leakage operating current ≤ 30mA).
The layout of power cable and signal cable should be orderly and not affecting each
other.
11
A B C D E F G H
IPH20 324 590 308 349 894 250 74 648
IPH25 324 590 308 349 894 280 74 648
IPH28 324 590 308 349 954 340 74 648
IPH35 324 590 308 349 954 340 74 648
IPH45 404 590 388 429 954 390 74 648
IPH55 404 590 388 429 954 460 74 755
IPH70 404 720 388 429 1084 620 74 948
IPH70T 404 720 388 429 1084 620 74 948
IPH100T 514 790 498 539 1154 650 74 948
E
B
C
A
FG
D
H
Size(mm)
Model
Name