3.22 SAFETY THERMOSTAT REMOVAL
Open oven control panel as detailed in Section 3.2.1.
Remove RH outer side panel from appliance as detailed in Section 3.2.5.
Pull electrical connections off thermostat.
Slacken clip(s) which retain capillary tube to inside wall of controls compartment.
Undo nut which holds safety stat body to bracket and remove from bracket.
Open oven doors and remove grid shelves.
Remove inner oven back and right hand linings as detailed in section 3.2.4, thus exposing
thermostat bulb.
Remove thermostat bulb from bracket and slacken clip which retains capillary tube to oven wall.
Withdraw thermostat, feeding capillary tube and bulb through hole in oven wall.
Replace in reverse order, taking care to replace insulating sleeve on the capillary tube, and to coil
excess tubing out of the way of live parts.