From phone: 410 #
Deleting message 1:
From keypad:
From phone:
# 410 #
Note: Resetting to default setting (P990P) will not clear the speech messages.
Speech message 2; for the alarm receiver
This message is played in the receiving telephone before the alarm call has been acknowledged
by the alarm receiver. It is stopped by pressing any digit on the receiver telephone. For simpli-
fied and disconnected acknowledge the message 2 is only played once. The receiver can re-
peat the message 2 at any time during the call by pressing ‘1’ on the telephone handset.
Recording of message 2:
From keypad: < wait for tone; read message. Max 16 seconds >
From phone:
420 < wait for tone; read message. Max 16 seconds > #
Listening to message 2:
From keypad:
From phone:
420 #
Deleting message 2:
From keypad:
From phone:
# 420 #
Note: Resetting to default setting (P990P) will not clear the speech messages.
Broken button detection
If the alarm button is continuously closed or open the ECII™ Flex will allow 15 emergency
alarms. The ECII™ Flex will then send a technical alarm (alarm code 5) and restrict the emer-
gency alarms to once every 8 minutes. This function is default activated.
To deactivate the broken button detection:
From keypad:
From phone:
# 350 #
The function is reactivated with:
From keypad:
From phone:
350 #
162187 Manual FältCom ECII™ Flex Page 32 of 40