www.fastech.co.kr
63
10. Control I/O Signal
13) JPT(Jump Position Table) StartInput
To select motion pattern(position table number) to be subsequently executed according to
input signal conditions. The difference from Paragraph 13) JPT Input0~Input2 Input
is:
1) PT number to be jumped must be composed to 10XXX;
2) Next motion is not executed until JPT Start is set to ON. If Wait Time value
of PT data is more than 0, the time lapses additionally and then next motion is
executed.
Example
PT 14 Data
PT No.
Wait Time
JP Table No
JPT 0
JPT 1
JPT 2
14
500
10015
10115
10116
10255

Table of Contents