www.fastech.co.kr
13) ‘JPT(Jump Position Table) Start’Input
To select motion pattern(position table number) to be subsequently executed according to
input signal conditions. The difference from Paragraph 「13) ‘JPT Input0~Input2 Input」
is:
1) PT number to be jumped must be composed to 10XXX;
2) Next motion is not executed until ‘JPT Start’ is set to ON. If ‘Wait Time’ value
of PT data is more than ‘0’, the time lapses additionally and then next motion is
executed.
【Example】
PT 14 Data