P-MAX DIAGNOSTICS
Active Charge Assembly
Drain Barrel until tank pressure is 0 Psi
Verify active charge regulator is 2 to 4 Psi above the “FULL” pressure
using tire gauge, adjust if needed.
Expansion Tank
Verify if there is a torn bladder by determining whether syrup is on
CO2 side of expansion tank
Solution & CO2 Module
Check solenoid seal for tear
Check solenoid seating is properly installed
Pressure Transducer Offset or Harness
Check power to pressure transducer is 3.3 DCV
Plug into the known pressure and verify pressure readout