56X Setup Requirements
FBD FROZEN DISPENSER SETUP FOR FCB
562/563 564
AC RC WC High Cap
AC RC WC
Electrical Requirements
Supply Voltage [Volt]
215 245 LCD readout should be +/- 2 volts of measured voltage at L1 and L2
Current Rating [Amp]
20 30 30
Incoming Pressure and Flow Requirements
Incoming CO2 (PSI)
70-72
Regulated CO2 (PSI)
22-24
Water Pressure (PSI)
85-92
Syrup Pressure (PSI)
70-72
Active charge Pressure (PSI)
28 - 30
Water Flow Rate at solution module
15oz per 10 second
Brix
13.5 - 15.0
Spacing Requirements
Top
12 inches
Sides
2 inches
Rear
2 inches
Tubing Requirements
CO2
3/8"
Water
3/8"
Syrup
3/8"