Preventive Maintenance
1. Manually activate CO
2
Solenoids to assist emptying barrels.
2. Deactivate all CO
2
Solenoids and depressurize barrels.
3. Perform visual inspections for leaks
4. Replace rear seals per PM recommendation, and repair DDV valve as needed.
5. Sanitize unit following recommended procedures.
6. Clean air filter.
7. Follow “Initial Start-Up and Freeze” procedure to start machine
54
Recommended replacement time: 6 months
Approximate PM time for 564: 1.5 hours
PM Parts Needed
Rear Seals
Dow 111 lubricant