APPENDIX C - APPROVAL INFORMATION FLT
®
Series FlexSwitch
TM
86 Fluid Components International LLC
Annex 1 to Certificate of Conformity IECEx DEK 14.0080X, issue 0
Annex 1 to IECEx TR NL/DEK/ExTR14.0088/00
Annex 1 to EU Type Examination Certificate KEMA 02ATEX2166 X, issue 4
Page 4 of 5
Thermal data
The relation between temperature class, maximum surface temperature, ambient temperature and
process temperature of the different configurations are indicated below.
Integral version
Integral enclosure in single cable entry variant:
Integral enclosure in dual cable entry variant:
Remote enclosure + electronics
Remote enclosure in single cable entry variant:
Temperature class
Maximum surface temperature
Ambient temperature
T6
T85 °C
-40 °C to +60 °C
Remote enclosure in dual cable entry variant:
Temperature class
Maximum surface temperature
Ambient temperature
T6
T85 °C
-34 °C to +60 °C
Local enclosure + sensor
Local enclosure in single cable entry variant:
Local enclosure in dual cable entry variant:
Temperature class
Maximum surface temperature
Ambient temperature
Process
temperature
T4
T135 ºC
-40 °C to +45 °C
-40 °C to +45 °C
T3
T200 ºC
-40 °C to +65 °C
-40 °C to +110 °C
T2
T300 ºC
-40 °C to +65 °C
-40 °C to +177 °C
Temperature class
Maximum surface temperature
Ambient temperature
Process
temperature
T4
T135 ºC
-34 °C to +45 °C
-34 °C to +45 °C
T3
T200 ºC
-34 °C to +50 °C
-34 °C to +110 °C
T2
T300 ºC
-34 °C to +50 °C
-34 °C to +177 °C
Temperature class
Maximum surface temperature
Ambient temperature
Process
temperature
T4
T135 ºC
-40 °C to +45 °C
-40 °C to +45 °C
T3
T200 ºC
-40 °C to +65 °C
-40 °C to +110 °C
T2
T300 ºC
-40 °C to +65 °C
-40 °C to +177 °C
T1
T345 ºC
-40 °C to +65 °C
-40 °C to +260 °C
Temperature class
Maximum surface temperature
Ambient temperature
Process
temperature
T4
T135 ºC
-34 °C to +45 °C
-34 °C to +45 °C
T3
T200 ºC
-34 °C to +50 °C
-34 °C to +110 °C
T2
T300 ºC
-34 °C to +50 °C
-34 °C to +177 °C
T1
T345 ºC
-34 °C to +50 °C
-34 °C to +260 °C

Other manuals for FCI FLT93L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FCI FLT93L and is the answer not in the manual?

FCI FLT93L Specifications

General IconGeneral
BrandFCI
ModelFLT93L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals