Parameter
value
Response
threshold
value
Sensitivity (∆ f/f)
0 4 0.02 % maximum sensitivity
1 10 0.04 %
2 20 0.08 %
3 30 0.13 %
4 40 0.17 %
5 50 0.20 %
::
11 110 0.46 %
12 120 0.5 % (Factory setting)
13 130 0.54 %
::
41 410 1.71 %
42 420 1.75 %
43 430 1.79 %
::
100 1000 4.17%
::
255 2550 10.63 % lowest sensitivity
Note: The response thresholds of the VEK S4 are different from the response threshold of the VEK M4D for
the same sensitivity (∆ f/f).
10.3 Hysteresis drop (4Ch)
In order to avoid an intermediate loss of the occupied signal for vehicles with a high undercarriage such as
articulated buses, trams, trucks with trailers etc, it is possible to modify the switching hystereses. An
interruption-free detection of critical vehicles is then also possible with low closure resistance setting. The