Page #18 background imageLoading...
Page #18 background image
Page 18
SMILE VDSSMILE VDS
SMILE VDSSMILE VDS
SMILE VDS
SMILE VDSSMILE VDS
SMILE VDSSMILE VDS
SMILE VDS
To access the ADMINISTRATOR menu
0 0 0 0
2. Enter the administrator code, which by
default is 4444 (it may be changed).
The first number is blinking, each time you
press + or - it increases or decreases this
number.
When the administrator code has been
entered you access the configuration
menu screen appears.
- : Decrease button selected with the cursor.
+ : Increase button selected with the cursor.
: This moves to the next digit and replaces the previous one with *.
: It restarts with the first digit.
Notes:
- After entering 3 continuous erroneous codes the monitor will be blocked for 5 minutes.
- RESET the Administrator code.
If the installer has changed the code and does not
remember it, you may restore the default code. Enter the default code 3 times (4444),
even if an error appears (showing the digits in red).
3. Once the installer has accessed the configuration menu screen, the screen options
appear, (use the cursor to move them). The firmware version appears in the right
corner of the screen:
.
Default selection:
a) codes option (white line under the icon). Press . The following screen will appear:
FW v1.0FW v1.0
e
g
f
a
b c
d