B General
Brewer Operation Control Settings, Adjust Brew Flow Rate
POSITION Program Items Factory set Default Programming Range Increments Notes
B1 Tank Temp.
200°F-or-93° C
NOTE: Equipment is
Fahrenheit by default
77° to 97°C
170°F to 207°F
0.5°C
1.0°F
Chart to correct for high
altitude below
B2
Brew at Temp.
“YES”
ON/OFF
YES/NO
SEE NOTE BELOW
B4
Show Tank
Temperature
YES YES/NO
To display HW tank
temperature on screen
B5
Units of Measure
TEMPERATURE
° Fahrenheit Fahrenheit/Celsius C/F
NOTE: Overwrites user
settings (see page 9)
B6
Units of Measure
VOLUME
Gallons Gallons/Liter/Ounces L/Gal/Oz
NOTE: Overwrites user
settings (see page 9)
B7 Customer Name Off NO or YES For name on screen
B7 Customer Name (only if above is “ON)
Scroll with batch
keys
A-Z;a-z;0-9 16 characters total
B9 Demo Mode DEMO ON/OFF
Demonstrates the controls for
training. Disables all
components in demo mode
B10 Eco Mode On ON/OFF YES/NO
If Selected: Lowers hot water
tank temperature after preset
time of inactivity
B11 Eco Idle Time 1Hr 1-6 hours 1 hour
Time of inactivity to go into
ECO Mode
B12 Eco Idle Temp 170°F 158-176°F 1 degree
Temperature that hot water
tank is lowered to when in
ECO Mode
B13 Filter Life OFF ON/OFF YES/NO
Water filter life is accessed in
G-Counters. This is user set
and will display indicator to
change water filter
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
0
0
205
212.0
96
100.0
500
152
205
211.0
96
99.5
1000
305
200
210.1
93
98.9
2000
610
200
208.1
93
97.8
2500
762
200
207.2
93
97.3
3000
914
200
206.2
93
96.8
3500
1067
197
205.3
92
96.3
4000
1219
195
204.3
91
95.7
4500
1372
194
203.4
90
95.2
5000
1524
194
202.4
90
94.7
5500
1676
193
201.5
89
94.2
6000
1829
192
200.6
89
93.6
6500
1981
191
199.6
88
93.1
7000
2134
190
198.7
87
92.6
7500
2286
188
197.8
86
92.1
8000
2438
187
196.9
86
91.6
8500
2591
185
196.0
85
91.1
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: “ON
(FACTORY DEFAULT FOR BREWER)
“BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show “HEATING”
and hot water tank temperature
The “BREW START” entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
will
allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-will
allow brew at low temperature.
Coffee flavor will be noticeably affected
Hot water tank not at
brew temp setpoint.
Tank temp
STOP is not lit
BREW START
buttons not lit.
and are disabled
.
When
hot water tank
temperature is at
setpoint.
Buttons will
illuminate and
“READY” will be
displayed
vv
vv
vv
HEATING
160°F
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at cold temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off