EasyManua.ls Logo

Fiat Capron A461 - Battery Charging Issues

Fiat Capron A461
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
140 Capron - 04-17 - CAP-0017-01EN
Troubleshooting
15
Starter or living area
battery is not charged
when operated in 240 V
mode
Jumbo flat fuse (40 A) on
the starter or living area
battery is defective
Replace jumbo flat fuse
(40 A) on the starter or
living area battery
Charger module in the
transformer/rectifier is
defective
Contact customer service
Living area battery is not
charged during vehicle
operation
Fuse on terminal D+ of
the alternator is defective
Replace fuse
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V indicator lamp does
not light up
12 V power supply is
switched off
Switch 12 V power
supply on
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Starter or living area
battery is not charged
Charge the starter or
living area battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
Flat fuse (2 A) in the
living area battery is
defective
Replace flat fuse (2 A) in
the living area battery
12 V power supply does
not work
12 V power supply is
switched off
Switch 12 V power
supply on
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Living area battery is
discharged
Charge the living area
battery
Jumbo flat fuse (40 A) on
the living area battery is
defective
Replace jumbo flat fuse
(40 A) on the living area
battery
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V power supply does
not work in 240 V
operation
12 V power supply is
switched off
Switch 12 V power
supply on
Battery cut-off switch on
the transformer/rectifier is
switched off
Set battery cut-off switch
to on
Charger module in the
transformer/rectifier is
defective
Contact customer service
240 V automatic circuit
breaker has triggered
Contact customer service
Jumbo flat fuse (40 A) on
the living area battery is
defective
Replace jumbo flat fuse
(40 A) on the living area
battery
Fault Cause Remedy

Table of Contents

Related product manuals