144 Capron - 04-17 - CAP-0017-01EN
Troubleshooting
15
15.8 Refrigerator
In the event of a defect contact the nearest customer service workshop of the
relevant appliance manufacturer. The list of addresses is enclosed with the
accompanying appliance documentation. Only authorised qualified personnel
may repair the appliance.
For certain faults, indicators also flash on the operating panel.
Fault Cause Remedy
240 V operation faulty No 240 V power supply Connect 240 V power
supply
240 V automatic circuit
breaker has triggered
Switch on the 240 V
automatic circuit breaker
240 V operating voltage
too low
Have the 240 V power
supply checked by an
authorised specialist
workshop
12 V operation faulty 12 V operation is only
possible when engine is
running
Start the engine or select
a different operating
mode
Fuse on the transformer/
rectifier is defective
Replace fuse on the
transformer/rectifier
Disconnector relay in the
transformer/rectifier is
defective
Contact customer service
12 V operating voltage
too low
Have the 12 V power
supply checked by an
authorised specialist
workshop
Gas operation faulty Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Air in the gas pipe Start refrigerator between
2 and 3 times
Cobwebs or burnt
residue in the burning
chamber
Remove the ventilation
grill on the outside of the
vehicle and clean the
burning chamber
Refrigerator does not
refrigerate sufficiently
Insufficient ventilation of
unit
Check if ventilation grills
are covered; remove
covers if necessary
Remove ventilation grills
and clean the space be-
hind them (of leaves etc.)
Ambient temperatures
are too high
Remove the ventilation
grills periodically
Refrigerator is at too
much of an angle
Position the vehicle
horizontally
Too much ice on the
cooling fins
Defrost the refrigerator