6.5 Memory Accumulation Function
6.5.1 To Accumulate a Transaction to Memory
12
13
14
a. Press [M+]
15
to save and accumulate data of current transaction to
memory,
b. This instrument displays n”. M+ Indicator appears to indicate that
memory contains stored data. n”” means the total number of
transactions accumulated to memory,
c. This instrument returns to normal display status after 2 seconds,
d. Repeat a to c for subsequent transactions
16
,
Note: -
1. Unstable weight will not be accumulated. If M+ is pressed when
weight reading is not unstable, this instrument will reject this
command and response with 3 beeps.
6.5.2 Memory Recall and Clearance
a. Press [MR] to recall total accumulated weight from memory,
After [MR] is pressed, Mr Indicator appears to indicate the total
accumulated weight value is displayed. At the same time, instrument
displays n(n means the number of transactions accumulated) follow
by the total accumulated weight stored in memory,
b. At this point: -
Press [Zero] to quit, or
Press [MR] again to clear memory then press [Zero] to quit to
operation mode. After that, both MR and M+ Indicator disappear to
indicate no data is stored in memory.
12
Memory Accumulation Function support weighing function only.
13
Weight less than 20d (or 20d
1
for dual range) will not be accumulated to memory.
14
All data stored will be erased when this instrument is powered off.
15
or press [PRINT] if F17 is = ON
16
Weight must return to or below zero to enable another weight accumulation.