24
6.6 Piece Count Function
17
This instrument is equipped piece count function. Follow the below steps to
enter Piece Count Function: -
a. Refer to 6.3 on how to select the desired weight unit,
b. If a container is used, place it onto the platform and press [Tare],
c. Press [Func] until (CoUnt) appears,
d. Press [Print] to enter,
e. Default
18
sample size appears.
f. Refer to 6.7 for subsequent operation procedures.
6.7 Sampling Process
a. Put samples with same quantity on platform then press [Print]. Should
a different sample size is required, enter the quantity of the sample
size
19
through [M+], [Unit] and [Func] keys,
b. Apply samples with the same quantity as being displayed on this
instrument
20
and press [Print],
c. This instrument will calculate, store the average piece weight and
confirm with 2 beeps. The quantity applied to platform is then displayed,
d. Sampling process is now completed.
Add to or remove from the platform, the corresponding quantity will be
displayed automatically.
Note: - To count different articles, press [Func] and repeat procedures listed
on 6.6 and 6.7.
17
Piece Count Function Mode does not support memory accumulation (M+) function.
18
Default sample size value = 50 pieces
19
Usually, the more the sample size, the better the counting accuracy.
20
Although there is no restrictions on the minimum average price weight, for counting
accuracy, it is recommended that the average piece weight should not be less than 0.25d