3332
Certifications and
Module IDs
UL 61010-1, Third Edition
EN61010-1, EN61010-2-032
EN61010-2-033, EMC EN61326-1
FCC ID: 2ALHR005
RCM (N22675)
WEEE
Restriction of Hazardous
Substances Compliant
IC: Industry Canada IFETEL: Federal Telecom Institute
22518-BT005 RCPFI2A19-0287
CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated and
have removable safety caps.
CATIII 1000V, CATIV 600 class II and pollution degree 2 indoor use comply
with CE, RoHS compliant.
CATIII is designated for measurements performed in the building
installation.
CATIV is for measurements performed at the source of the low-voltage
installation.
Specifications
Display: 10000 count dual display
Backlight: 5 minute duration with auto-off, blue color
Overrange: “OL” or “-OL” is displayed
Measurement rate: 3.3 times per second, nominal
Zero: Automatic
Operating environment: 32°F to 122°F (0°C to 50°C) at <70%RH
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80%RH (with
battery removed)
Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to 19°C
(32°F to 66°F), 28°C to 50° C (82°F to 122°F)]
APO (Auto Power Off): Approx. 30 minutes
Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life: 100 hours typical alkaline (No wireless, no backlight)
Low battery indication: Battery icon blinks and "batt" is displayed
when the battery voltage drops below the operating level
Dimensions: 301.5mm(H) x 79.5mm(W) x 50.0mm(D)
Weight: Approx. 480g including battery
Altitude: Up to 6562 ft (2000m)
Overload protection: 1000VDC or 750VAC rms unless otherwise stated
Test leads: Use UL listed test leads that comply to UL61010-031 rated
CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated
and have removable safety caps.
Please operate the instrument following all instructions of
the operator's manual to avoid impairing the safety of
the product.