10
! The AUTO-COMPENSATION FLOW CONTROL feature, which is standard on
the Filtrabox, will maintain the set-point “Airflow %” by automatically
increasing power to the blowers as the filters get obstructed by the dust. You
do not have to manually change the “Airflow %” setting again – unless you
change your laser or use a more fume generating substrate. Note: “Airflow
%” represents the Airflow potential of your system.
! If the AIRFLOW% setting is greater than 90%, the Filtrabox display will
change color and show a “REDUCE FLOW RECOMM.” This is because if the
machine is used past 90%, filter life will be severely reduced, please contact
Filtrabox if your laser setup requires very high flow settings.
YOUR FILTRABOX LASER EXTRACTOR IS
NOW SET-UP FOR OPERATION.