11
FILTER REPLACEMENT
! When the “CAPACITY WARNING” comes on, increasing the “Airflow %” value
WILL NOT increase actual airflow. The “Check Filter” warning indicates that the
“Airflow %” set-point can no longer be achieved despite the fact that the power
applied to the blower by the “AUTO-COMPENSATION FLOW CONTROL” feature
is at maximum value. This is most likely due to airflow blockage in the Pre-filter
or HEPA filter from normal usage.
The Filtrabox Micro system has 3 types of filters; Pre-Filter, HEPA filter and Gas Filter.
1. Pre-Filter FIL-P-MC-426: Collects Fine Dust
2. HEPA Filter FIL-P-MC-416: Collects Ultra-Fine Dust
3. Gas Filter FIL-G-MC-406: Adsorbs and destroys odor causing gases.
All three filters will need to be independently replaced at some point in time during the course of
normal usage. Follow the “Filter Installation” instructions for the depleted filter to replace it properly.
CAPACITY WARNING
! Replacement filters can be purchased from your dealer where you purchased
this product or: info@filtrabox.com or call 514.840.9696 ext. 102
The CAPACITY WARNING will appear on the screen when either Dust filters (Pre-Filter and/or the
HEPA) filter need replacement.
When the CAPACITY WARNING comes on, increasing the “Airflow %” value WILL NOT increase actual
airflow. The CAPACITY WARNING indicates that the “Airflow %” set-point can no longer be achieved
despite the fact that the power applied to the blower by the Dynamic Flow Control feature is at
maximum value. This is most likely due to airflow blockage in the Pre-filter or HEPA filter from normal
usage.