12
“FILTER CHECK” FEATURE
! Useful Tip: Check for obstructions in the hose first before ordering a new filter.
An obstruction in the hose may cause erroneous “CAPACITY WARNINGS”
! Important Note: The Filter Alignment Rings must be centered correctly into
each filter. They should fit inside both filters when installed correctly.
! Replacement filters can be purchased from your dealer or: info@filtrabox.com
or call 514.840.9696 ext. 102
1. If the “CAPACITY WARNING” comes on, go to the User Interface and press the MENU
button. Press the UP or DOWN keys to scroll through the menu functions until you find the
“CHECK FILTER” feature.
2. Press the OK button to initiate the “CHECK FILTER” process; follow the prompts on screen.
3. Filtrabox will first assess the status of the Pre-Filter, the machine will then display a prompt
to remove the Pre-Filter (refer to image below).
4. IMPORTANT! Loosen both Strap Clamps on the Lid by pressing the lever on the clamps.
Unhook the Strap Clamps and remove the Lid by lifting it straight up off the assembly.
5. Remove the topmost Filter Alignment Ring and the Pre-Filter and set them aside, then put
the Lid back onto the HEPA Filter as in the image below. Hook the Strap Clamps back onto
to the Lid and endure that they are tight.
6. Follow the prompts on screen so the Filtrabox can finish the procedure.
7. Filtrabox will then advise you to replace either the HEPA or the Pre-Filter depending on
their condition. If the filters are still in good condition, a Filter Life % will be displayed.
8. When the filter check is complete, replace the Pre-Filter and the topmost Filter Alignment
Ring making sure that the Strap Clamps are tightened.