EasyManua.ls Logo

finmon mi64 - Table 2 Programming Page Functions

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When adding these roles or functions, you will need to use the ‘programming
pages’ which are accessed using the corresponding P key. For example, Page 2
is accessed by selecting [P2]. See below:
Table 2 Programming Page Functions
Page Function Description
1 Assigning
partitions
Select the partition number followed by [*] to add
or remove partitions to and from a users profile.
Only partitions belonging to the profile of the
master code used to access programming mode may
be added or removed.
2 Assigning
user type
Touch the user type number followed by [*] to
enable and disable the options as per the user type
table below.
3 Add remote
functionality
Touch any button on an unused remote in order to
enrol it to this user. Only 1 remote may be assigned
per user code and only one user may be assigned to
a remote.
4 View the user
number
The user number is displayed in binary format.
You will also have to select a user type. See below for the options:
Table 3 User Type Values
Values User Type Description
1 Master Can add/remove and edit user codes
2 Duress A duress code will disarm the panel normally and a
duress signal will be sent to the alarm monitoring
company. This signals that a user has been forced to
disarm the panel under duress.
3 Arm to
Disarm
This code will only disarm a partition if the same
Arm to Disarm code was used to arm. This code
may be given to a user whom has limited access to
the premises.
4 Global
Arm/Disarm
A Global code will simultaneously arm and disarm
all partitions in a users profile. All partitions will
follow the status of the partition which was selected
at the time the code was entered.
5 Reporting The user code will report an open and a close when
arming and disarming.