User Manual
COMBINED STROBE
& VIBRATING PAD
W2-SVP-630

Other manuals for FireAngel Wi-Safe 2

Questions and Answers

  • M
    Mitchell EvansAug 18, 2025
    How to fix a FireAngel Wi-Safe 2 when the green power LED is off?
    • G
      groseAug 18, 2025
      If the Power (green) LED is not illuminated on your FireAngel Smoke Alarm, check that the power supply is plugged in and switched on at a working power socket.
  • J
    Juan NelsonAug 20, 2025
    Why is the amber light on my FireAngel Wi-Safe 2 Smoke Alarm staying on even when the green light is on?
    • B
      Breanna SmithAug 20, 2025
      If the power (green) LED is illuminated, but the Fault (amber) LED is continuously lit on your FireAngel Smoke Alarm, it means that the Low Frequency Sounder is not interlinked (“learned in”) to the rest of the network. If this happens regularly after learning in the unit, call Technical Support on 0800 141 2561.
  • S
    Samantha WallaceAug 22, 2025
    What to do if FireAngel Personal Care Products strobe and vibrating pad does not respond to a smoke or CO alarm test?
    • A
      Amy HuntAug 22, 2025
      First, verify that the alarm, strobe, and vibrating pad have been correctly interlinked. Next, ensure that the units are within the specified range. If the strobe and vibrating pad still don't respond, further assistance may be needed.
  • A
    acollierAug 25, 2025
    Why is the power (green) LED illuminated, and the fault (amber) LED continuously lit on my FireAngel Personal Care Products?
    • P
      Peggy HumphreyAug 26, 2025
      This indicates that the strobe unit is not interlinked with the rest of the network. If you have already interlinked the unit and this issue persists, further assistance may be needed.
  • S
    stephenmillerAug 27, 2025
    What does it mean if the fault (amber) LED double flashes rapidly on FireAngel Personal Care Products?
    • G
      Gabriel WilliamsAug 28, 2025
      This indicates that one or more alarms in the network are either missing, faulty, or have been disabled (removed from its base).
  • D
    Dominique OchoaAug 30, 2025
    What to do if the fault (amber) LED flashes once every 5 seconds continuously on FireAngel Personal Care Products?
    • A
      Amy PrinceAug 30, 2025
      Immediately restore mains power to the strobe unit. If the strobe unit has been plugged into the mains and switched on for at least 72 hours, the battery might be defective and require attention.
  • J
    Justin KingSep 2, 2025
    How to fix FireAngel Personal Care Products when the strobe is connected to power supply but the power (green) LED is not illuminated?
    • D
      David SmithSep 2, 2025
      Make sure the power supply is properly plugged into a working power socket and switched on.
  • B
    bennettsarahSep 4, 2025
    What to do if the FireAngel Personal Care Products vibrating pad does not vibrate when testing?
    • K
      Krystal LaneSep 4, 2025
      Check that the vibrating pad is correctly connected to the strobe. If it's correctly connected and the fault (amber) LED is flashing after 2 minutes, further assistance may be needed.
  • Y
    ypachecoSep 6, 2025
    What to do if the red LED is continuously showing on my FireAngel Security System?
    • M
      Michael JordanSep 7, 2025
      If the red LED is continuously illuminated on your FireAngel Security System, it indicates that the network is in alarm. You should respond immediately to address the situation.
  • W
    William ChoiSep 9, 2025
    What to do if the red LED flashes and a buzzer sounds every 60 seconds on my FireAngel Security System?
    • H
      hwilliamsSep 9, 2025
      If the red LED flashes and a buzzer sounds every 60 seconds on your FireAngel Security System, it means the batteries are low and need to be replaced. Replace the batteries to resolve this issue.

Summary

INTRODUCTION

KEY FEATURES

INSTALLING THE STROBE AND VIBRATING PAD

CONNECTING THE BATTERY;MAINS POWER

WIRELESSLY INTERLINKING THE WI-SAFE 2 STROBE AND VIBRATING PAD TO YOUR WI-SAFE 2 SMOKE OR CO ALARM

Learning a strobe into an existing Wi-Safe 2 system

Procedure to add a strobe to an existing Wi-Safe 2 network.

Network Reset

Steps to reset the wireless network configuration for Wi-Safe 2 devices.

Removing (“unlearning”) the Strobe from the wireless network

How to disconnect a strobe from its current wireless network.

TESTING THE WI-SAFE 2 STROBE AND VIBRATING PAD WITH SMOKE; CO ALARMS

Testing the network from the smoke alarm or CO alarm

How to test the interlinked network via a smoke or CO alarm.

Testing the network from the Strobe

How to test the interlinked network using the strobe unit.

Weekly Testing

Recommended regular testing schedule for the Wi-Safe 2 network.

POSITIONING

Position the Vibrating Pad

Guidance on optimal placement of the vibrating pad for effective use.

Position the Strobe

Guidance on optimal placement of the strobe unit for visibility.

INSTALLING THE STROBE

LIMITATIONS

OPERATION

Standby Mode, but not “learned in” to a network

Describes the device's state when not connected to a network.

Standby mode

Explains the device's operational state when powered but not in alarm.

Alarm mode

Details how the strobe and pad function during an actual alarm event.

Locate Feature

Functionality to silence alarms and help locate the source during an event.

UNPLUGGING FROM THE MAINS;POWER CUT

WHAT TO DO IF YOUR STROBE AND VIBRATING PAD GOES INTO ALARM

WHAT TO DO IN THE EVENT OF A SMOKE ALARM TRIGGERING THE STROBE AND PAD

What to do in case of a fire in your home

Essential safety procedures and advice for home fire escape.

WHAT TO DO IN THE EVENT OF A CARBON MONOXIDE ALARM TRIGGERING THE STROBE AND PAD

WHAT TO DO IN THE EVENT OF A CO ALARM

Critical actions to take when a carbon monoxide alarm is triggered.

REPAIR

DISPOSAL

WARRANTY

FireAngel Wi-Safe 2 Specifications

General IconGeneral
Wireless InterconnectYes
Power SourceBattery
Alarm Sound Level85 dB at 3 meters
Test/Hush ButtonYes
Operating Temperature0°C to 40°C
Sensor TypeOptical
Warranty10 years
Weight220g
TypeOptical
Standards ComplianceEN 14604:2005
Battery TypeSealed Lithium battery (non-replaceable)