10 YEAR LIFE
SMOKE ALARM
ST-622
WITH LOW BATTERY
WARNING SILENCE
Please read me – as I could save your life.
Please retain this user manual for future reference

Questions and Answers

Summary

INTRODUCTION

AUTOMATIC POWER ENGAGE

SENSOR TECHNOLOGY

Thermoptek Sensor Technology

Combines optical sensing chamber with thermal enhancement for faster response to fire types.

APPLICATION

Multi-family or mixed occupant residence

Use in flats/bedsits requires a primary fire detection system for common areas.

Institutions and Hotels

Use in individual rooms requires primary system for common areas.

Mobile Homes and Caravans

Smoke alarm suitable for use in mobile homes and caravans.

Commercial and Industrial Premises

Not intended for non-residential, commercial, or industrial applications.

POSITIONING

Locations to Avoid for Smoke Alarms

Avoid bathrooms, kitchens, dusty/dirty areas, draughty areas, insect infested areas, near fluorescent lights.

BEST LOCATION AND DEAD AIR SPACES

Best Location and Dead Air Spaces

Diagram shows best ceiling placement and illustrates 'dead air' spaces to avoid.

WHAT ARE THE LIMITATIONS OF MY SMOKE ALARM?

Audibility and Hearing Impairment

Alarm levels may be reduced by closed doors, walls, or noise. Not suitable for hearing impaired.

Product Limitations and Testing

May fail, not sense all fires. Test weekly and replace every 10 years.

HOW TO INSTALL YOUR SMOKE ALARM

Preparation

Break out mounting plate tabs, mark drill holes, drill and insert anchors.

Install Mounting Plate

Fit the mounting plate to the ceiling or wall using the screws provided.

Fit Your FireAngel Smoke Alarm

Align lugs on alarm with slots on mounting plate, twist clockwise until fully seated.

Test Your FireAngel Smoke Alarm

Wait 5 seconds after fitting, then test the alarm. Refer to 'Alarm Test' on page 10.

OPERATION

Normal Operation Condition

Red LED flashes every 40 seconds to indicate the alarm is active.

Low Power Pack Condition

Unit emits 'chirp' every 40 seconds. Replace alarm within 7 days.

Low Battery Warning Silence Feature

Temporarily silences low battery chirp for 8 hours. May be repeated up to 10 times.

ALARM SMART SILENCE

LOW BATTERY WARNING SILENCE

ROUTINE MAINTENANCE

Routine Maintenance: Testing

Test your smoke alarm once every week. Report test failures to Technical Support.

Routine Maintenance: Cleaning

Clean alarm every 3 months using a vacuum cleaner with a soft brush attachment.

WHAT TO DO IN CASE OF A FIRE IN YOUR HOME

REPAIR

TROUBLESHOOTING

Troubleshooting: No Sound During Testing

Ensure alarm is rotated correctly, test button pressed firmly, or wait if silenced.

Troubleshooting: Intermittent Chirps

Check location and confirm chirping source; rule out other alarms.

Troubleshooting: False Activation

Check location, clean the smoke alarm, or check for frequent unwanted alarms.

Troubleshooting: Low Battery Chirp Not Silenced

Low battery warning can only be silenced a max of 10 times. Replace alarm.

Troubleshooting: Frequent Unwanted Alarms

Check location, clean alarm, or contact support if issues persist.

Troubleshooting: General Failure to Operate

If alarm fails, seek manufacturer advice or contact Technical Support.

DISPOSAL

HOW TO MAKE YOUR HOME SAFER

Fire Safety Rules and Prevention

Proper smoking, match/lighter storage, flammable materials, electrical safety, cooker/fireplace cleaning.

Develop and Practice Family Escape Plan

Create floor plan, identify two exits per room, practice drills, recognize signal, teach children safety.

WARRANTY

RETURNS

PRODUCT RANGE

FireAngel Thermoptek ST-622 Specifications

General IconGeneral
Battery TypeSealed for life lithium battery
Power SourceBattery
Alarm Sound Level85 dB at 3 meters
Operating Temperature0°C to 40°C
Warranty10 years
InterconnectivityNo
Sensor TypeOptical
ComplianceEN 14604:2005