Let the generator run at no-load for two minutes to stabilize
internal temperatures of the engine and generator.
2. Remote Start Operation
Push and release the "STOP" button on the remote
control. The generator will be shut down.
Note: Skip this step and go to step 3, if you are not
using Remote Start to shutdown the engine.
If a cover is used, do not install until unit has
cooled.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section for
proper engine and fuel storage.
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between the LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is
corrected.
If oil level is below the LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again a
low oil condition may still exist. DO NOT try to
restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load
attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Overload Operation
The overload indicator light will turn on and cut
power to the receptacles after 30 seconds when
the load exceeds 3080W(approximately). The
overload indicator light will turn on and cut power
to the receptacles after 2 seconds when the load
exceeds 3150W(approximately). How to Correct