EasyManua.ls Logo

First Alert FA1600C

First Alert FA1600C
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 52 –
Programming Device Timers (cont’d)
00 DAYS? MTWTFSS
HIT 0-7 X X
Select the days on which the device is to be
activated by entering 1-7 (Monday = 1). An
"X" will appear under that day, indicating
the output for that day is active. Entering a
day's number again will deactivate that day.
Pressing 0 will turn all days on/off. The
outputs will only be in effect for the days
which have the letter x underneath them.
As the week progresses, the selected days
are reset to the inactive state, unless the
permanent option is selected (next screen
prompt). When completed, press * to
continue.
00 PERMANENT ?
0 = NO, 1 = YES 0
Answering 1 (yes) means the system will
continue executing this timer on a
continuous basis. An answer of 0 means
execute each day's output only once.