EasyManua.ls Logo

First Sales XTS30 - Page 13

First Sales XTS30
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
CAUTION: Changing the cycle durations will affect the water softener’s performance
and efficiency. The following settings should only be altered by a knowledgeable
water treatment professional.
Press ‘NEXT’ button to set incoming HARDNESS level.
Ensure the Hardness indicator is illuminated on the left side of
the display and using the ↑’ and ‘↓’ buttons set the incoming
hardness level.
NOTE: This softener is set to calculate hardness as
grains per gallon (gpg). If your water hardness is
reported in milligrams per liter (mg/l) or parts per
million (ppm) divide these results by 17.1 to convert to
grains per gallon.
Press ‘NEXT’ button to set regeneration
DAYS OVERRIDE interval
Using ↑’ and ‘↓’, set the desired day override interval. The
regeneration day override function will cause the softener to
regenerate after a designated period of no regeneration cycles. The
override interval will reset after every regeneration cycle whether
initiated manually or by volume. The day override function will be
disabled if the VACATION mode is active.
Press ‘NEXT’ button to set REGENERATION TIME hours.
Ensure the Regen Time indicator is illuminated. Using↑’ and ‘↓’,
set the desired time of regeneration hours. Note the AM
and PM indicator and set the time accordingly.
Press ‘NEXT’ button to set REGENERATION TIME minutes.
Ensure the Regen Time indicator is illuminated. Using↑’ and ‘↓’,
set the desired time of regeneration minutes.
Press ‘NEXT’ button to set PROPORTIONAL BRINING.
Press ‘NEXT’ button to set cycle #1 duration.
Using ↑’ and ‘↓’, the Proportional Brining function can be set to ON
or OFF. This feature can also be manually toggled on or
off with the ECO button on the face of the front panel.
(See additional information on Proportional Brining in the
ECO section of the instruction manual.)
Display and Operation Installer Settings Cycles (continued)