2nd LIGHT [ 1 ] 2nd START [2] 2nd IGN1 [3] 2nd ACC [4] STATUS [5] REARM [6]
DISARM [7] HORN [8] DOME LIGHT [9] AUX 1 [10] AUX 2 [11] DEFROST [17]
GWA [18] DEFROST 2 [21] LOCK [25] UNLOCK [26] PRIORITY UNLOCK [27]
TRUNK RELEASE [28] STARTER KILL [29]
IMPORTANT: System must be unlocked before you can set options with the OP500 or remotes.
*Once programmed, this feature requires activation from the remote. Please refer to the
remote user manual or the option description below.
Option Menu Descriptions
1-01
Unlock Before, Lock After Starting
:
FO1 - Off
FO2 - On:
Sends an unlock command as soon as the remote start sequence is triggered then send
a relock command as soon as the CM-900 has confirmed remote start success.
FO3 - Lock after start only:
Sends a lock command after the CM-900 has confirmed remote start
success.
FO4 - Lock after shutdown only:
will send a lock command only after the CM-900 has
successfully shut down.
Note: It will not provide an output if the CM-900 is shut down with an
emergency override input. (i.e. hood pin, or foot brake input)
1-02 Lock / Unlock Pulse Duration
: This does not affect the behavior of the factory arm output
(orange wire) or factory alarm disarm output (orange/white wire).
FO1 - 0.8 seconds:
(-) Negative lock and unlock output time.