FO2 - 2.5 seconds:
(-) Negative lock and unlock output time.
FO3 - 0.125 seconds:
(-) Negative lock and unlock output time. This option may be helpful when
using lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm
wires when the standard output is too long.
FO4- 3.5 seconds: (-) Negative lock and unlock output time.
1-03
Driver’s Priority Unlock
:
FO1 - Off:
(default)
FO2 - On: This feature will allow the user to unlock the driver’s door first. If the unlock button is
pressed again within 4 seconds, the other doors will unlock. The driver’s door unlock must be
isolated from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC
setting) is used to provide unlock output to unlock all other doors.1-04
1-04 Double Pulse Unlock
:
FO1 - Off:
(default)
FO2 - Unlock:
This option will provide a double pulse output
only
for unlock each time the CM-900
executes the unlock command. (Length of output time will be based on feature 1-02 option
settings.)
FO3 - Lock:
This option will provide a double pulse lock output
only
for lock each time the CM-900
executes the lock command. (Length of output time will be based on feature 1-02 option settings.)
FO4 - Lock and unlock: This option will provide a double pulse lock output for both lock and
unlock each time the CM-900 executes lock or unlock commands. (Length of output time will be
based on feature 1-02 option settings.)
1-05
Rearm Output
:
FO1 - After start, after shutdown, after first lock:
This option triggers the FAA
after every successful remote start, every successful remote start shut down, and with every first
lock command. (First lock command is the first arm/lock command sent after the CM-900 has been
disarmed or unlocked.)
FO2 - After shut down only and first lock:
This option triggers the FAA after every successful
remote start shut down, and with every first lock command. (First lock command is the first
arm/lock command sent after the CM-900 has been disarmed or unlocked.)
FO3 - After Start only:
This option triggers FAA after every successful remote start.
FO4 - After shutdown only:
This option triggers the FAA after every successful remote start shut
1-07
Unlock/Disarm With Trunk Release
:
FO1 - Unlock, Factory Alarm Disarm (FAD) trunk
releas:
This option will send unlock and FAD outputs prior to sending the Trunk release output.
This applies to analog and data to data situations.
FO2 - Factory Alarm Disarm (FAD) with trunk release:
This option will send the FAD output
prior to sending the trunk release output. This applies to analog and data to data situations.
FO3 - Trunk release only: This option will only send the trunk release output when triggered. This
applies to analog and data to data situations.
1-09 Ignition Controlled Locks
: When FO 2-4 are selected, the user can activate the “drive lock” or
ignition controlled door locking feature using a Firstech remote or Drone.
(Please check specific
remote user’s manual for steps to activate Drive lock.)
FO1 - Off:
(default)
FO2 - On:
This option (when activated with the Firstech remote or Drone) will provide a door lock
output when the foot brake is applied or 12 Volts is applied to the foot brake input on the CM-900.