FO2 - Enabled:
this feature will allow the end user to activate or deactivate the siren or horn mute
control.
2-01 Tach Sensing Method:
This feature will determine the point at which the CM-900 releases the
starter based on the sampled tach method.
FO1 - Optimal Tach reading:
This option will allow the CM-900 to sample the tach signal several
times during tach programming and select the optimal tach voltage at which to release the starter.
FO2 - Previous tach reading: This option will set the CM-900 to record the idle voltage which it is
being programmed. The CM-900 will release the starter once the idle tach voltage is met.
2-03 Diesel Timer:
Note: OP500 required to adjust time from any of the default settings,
will show up as DISL on the top line of text when option 2 or 3 are enabled.
This feature
provides a timed alternative solution to a hard wired glow plug input to enable the CM-900 to wait
to start.
FO1 - Wire:
(default) This option will allow the CM-900 to read input on brown/white wire. (PIC3) It
may be connected to a wait to start indicator on a diesel vehicle. When the CM-900 sees (-)
negative input, it will delay the crank output for 99 seconds or until negative signal has been
removed.
FO2 - Program (3-99 seconds):
default setting is 12 seconds. This option allows the installer to
adjust the time in 1 second increments that the CM-900 waits before cranking the starter.
FO3 - 7 seconds:
This option offers a fixed 7 second delay before providing starter output.
FO4 - GM Ignition delay: This option is designed to delay the ignition output 250mS during the
remote start procedure. This allows for the accessory to output first, then ignition, to simulate
normal key starting. There are some vehicle models that may require this additional delay in order
for it to remote start properly.
2-04
Trigger Start:
This feature changes the number of pulsed inputs (min of 60mS per pulse) on the
trigger start input wires. (red or red/white wires CN3).
Note: If option 3 is selected and OEM
remote control feature is available through data, the Control Module will accept 3 OEM lock
commands to activate the start sequence. FO1 - Off:
(default)
FO2 - Single pulse:
This option will trigger the remote start sequence with a single pulsed input to
the trigger start wire. This is ideal when adding accessories that can trigger the CM-900.
FO3 - Double pulse:
This option will trigger the remote start sequence with 2 pulses to the trigger
start input wire. This can be used when integrating with an OEM keyless entry remote.
FO4 - Triple pulse: This option will trigger the start sequence with 3 pulses to the trigger start
input wire. This is ideal when trying to integrate the OEM keyless entry remote. Note: this option
will also allow the CM-900 to accept a 3 pulse input from OEM remote commands through data.
2-05 Cold or Hot Start:
Note: the Firstech Thermister (FT-TEMP SENSOR) temp sensor must be
connected to the CM-900 in order to use these options.
This feature turns on the cold/hot
Timer start features.
FO1 - Off:
(default)
FO2 - Cold start:
This option enables the thermister when using Timer Start Mode. It will start the
car at the preset cold temperature (see feature 2-08) according to the selected timer start option
(see feature 2-06)
FO3 - Hot Start: This option enables the thermister when using Timer Start Mode. It will start the
car at the preset hot temperature (see feature 2-09) according to the selected timer start option.
(see feature 2-06)