IMPORTANT:
The OP500 is required to change settings in Special Option Groups 1 and 2.
Special Option Group 1
FO1- Diesel Timer:
(Option 2-03 must first be set to setting 2.) This special option allows a
specific wait to start time (in seconds) to be programmed. This prevents the need for a timer relay
and eliminates a connection to the “wait to start” wire.
FO2 - Aux 1 Output Timing: (Option 4-01 must first be set to setting 4.) This special option allows
a specific output duration for Aux 1 to be programmed 1-99 seconds. Note with OP500 update,
latched output time 1-15 minutes are available for programming in addition to the standard
1-99 seconds.
FO3 - Aux 2 Output Timing:
(Option 4-02 must first be set to setting 4.) This special option allows
a specific output duration for Aux 2 to be programmed 1-99 seconds.
Note with OP500 update,
latched output time 1-15 minutes are available for programming in addition to the standard
1-99 seconds.
Special Option Group 2
This special option group allows you to determine the output type of the POC wire. For example, if you
want to set POC #5 (default setting status out) to Aux 1, you will need change special option 5 to number
10. This must be done with the OP500.
POC 1 Green/White Negative Parking Light Output:
(default setting) This channel will
provide a 250mA (-) negative output when the CM-900 is armed
(function also POC setting 1)
POC 2 Blue/Green Lock:
(default setting) This channel will provide a 250mA output with the
lock/arm command.
(function also POC setting 25)
POC 3 - Blue • Unlock:
(default setting) This channel will provide a 250mA output with the
unlock/disarm command.
(function also POC setting 26)
POC 4 - Black • GWR (ground when running aka status output):
(default setting) This channel
will provide a 250mA output with the remote start activation command and continue to provide
output until 100mS after the remote start process has shut own.
(function also POC setting 5)
POC 5 - Orange • FAA (Factory Alarm Ream):
(default setting) This channel will provide a
250mA output with the lock/arm command. Note: the CM-900 will provide this output approx.
100mS before the unlock output.
(function also POC setting 6)
POC 6 - Orange/White • FAD (Factory Alarm Disarm):
(default setting) This channel will provide
a 250mA output with the unlock/disarm command.
Note: the CM-900 will provide this output
approx. 100mS before the unlock output. (function also POC setting 7)
POC 7 - White • Horn:
(default setting) This channel will provide a 250mA output when Horn is
triggered.
(function also POC setting 8)