CM2500 Feature tables
#1 Feature group 1
Option Setting
Default(I) Option (II) Option (III) Option (IV)
1-01 Door Pulse Duration 0.8 sec 2.5 sec 0.125 sec 3.5 sec
1-02 Double Pulse Locks Off Unlock Lock Both
1-03 Drivers Priority Off On
1-04 Ignition Locks
Ignition + Foot Brake
after Doors Closed
Ignition + 30 sec
after Doors Closed
OFF
1-05 Siren Duration 30 Seconds 60 Seconds 120 Seconds Chirp for 20 Seconds
1-06 Confirmation Chirps Medium (30ms) Short (15ms) Normal (60ms)
1-07 Auto Rearm Off 30 Seconds 60 Seconds 5 Minutes
1-08 Passive Arming Off On
Passive Without
Locks
Passive
Locking/Arming with
RFID
1-09 Dome Light Delay Off 5 Seconds 45 Seconds Auto
1-10 Valet
Key 5 times, or Remote
while Ignition is on
Key 5 times or Remote
(I+III)
(PIC) NEG. trigger
Valet Input
1-11 Door Open Notify On Off
1-12 Security features On Off
1-13
Siren/Horn Mute
Control on Remote
Disabled Enabled
1-14
CN4 Pin 6 (+) Input
Usage
(+) Door Input (+) Foot Brake Input
1-15 RFID Unlock Unlock FTX Off