www.firstechonline.com
|
www
.compustar.com
Copyright 2022 Fi rstech , LLC. “Are you not entertained…?” Page
21
Universal Security Control Module
Install.myfirstech.com
CM2500
Master
Guide
#2 Feature group 2
Option settings
Default(I) Option (II) Option (III) Option (IV)
2-01 Horn Output On double lock On Lock and Unlock Alarm Only
2-02 Horn Honk Pulsed Latched
2-03
(-) GWA (-)ground While
Armed
Latched while armed 0.5 sec 20 Seconds Program → Aux 4
2-04 Dome Light Output
Off Factory Rearm + 45
sec
Factory Rearm 45 Seconds Off
2-05
Unlock/ Disarm with
trunk release
Unlock, Factory
Disarm,
and Trunk Release
Factory Disarm,
Trunk Release Only
Trunk Release Only Aux 3
2-06 Trunk Output Timing 1 sec 0.5 sec 2 sec Program → Aux 3
2-07 Secure Aux Output On While armed On Off
2-08 Aux 1 Output .5 Seconds Latched 20 Seconds Program
2-09 Aux 2 Output .5 Seconds Latched 60 Seconds Program
2-10 Aux 1 Output Control By Remote Arm Disarm Ignition Off
2-11 Aux 2 Output Control By Remote Arm Disarm With full alarm
2-12 Shock Sensor Input Shock/Tilt
1st input : Disable
Arm/ Disarm
2nd input : Trigger
1st input : Prewarn
2nd input : Trigger
DAS Sensor
2-13
Sliding door Control for
iDatalink Modules
Off
Unlock, Factory
Disarm,
and Sliding Door
Control
Factory Disarm and
Sliding Door Control
Only
2-13
2-14 Soft Disarm OFF ON Disarm alarm 1 press