www.firstechonline.com
|
www
.compustar.com
Copyright 2022 Fi rstech , LLC. “Are you not entertained…?” Page
22
Universal Security Control Module
Install.myfirstech.com
CM2500
Master
Guide
#3 Feature group 3
Option settings
Default(I) Option (II) Option (III) Option (IV)
3-01 Gray port Drone FT-KP2 1-Way RFID ANT
3-02 FT-KP2 LED Flash While armed OFF while armed
3-03 FT-KP2 Sensitivity Normal Sensitivity High Sensitivity Low Sensitivity Lowest Sensitivity
3-04 Secure Start N/O Timer Off 2 min 4 min
Prog. 1-10 min (10 min
default)
3-05 Secure Start N/C Timer Off 1 min 2 min 4 min
3-06 Starter-kill output Starter-kill / GWA Secure start N/C Secure Start N/O
3-07 BLACK DATA PORT IDATALINK 2-WAY DRONE
S-#1
Special option group 1
Settings
1
AUX1 output time
1 ~ 99 [seconds],
LA(Latch)
2
AUX2 output time
1 ~ 99 [seconds],
LA(Latch)
3
AUX3 output time
1 ~ 99 [seconds],
LA(Latch)
4 AUX4 output Time 1 ~ 99 [seconds],
LA(Latch)
5 Secure Start Time 1-10 Minutes, with OP500 update v.36+
S-#4
Special Option group 2 Setting Value
Programmable Relay Control Options
1 PRC #1 (Default: Parking light) Parking Light [ 1 ] Priority Unlock [ 5 ] Aux2 [ 9 ]
2 Horn [2] Trunk Release [6] Rearm [10]
3 Lock [ 3 ] Dome Light [ 7 ] Disarm [11]
4 Unlock [ 4 ] Aux1 [ 8 ]