Fault Code Problem Solving Charts
The following charts can be used as a guide to help locate faults in a
DishDrawer. Answer each question with a yes or no and follow the
instructions inside the relevant box.
F1 The flood switch has been activated for more than 6 seconds
Question Yes No
1 Is there a F1 on both
displays?
Go to Question 2 If power fails to the
bottom tub it will cause
the top tub to go F1.
Test heater plate.
2 Has a flood occurred?
(N.B. The flood may
have dried up)
Go to Question 3 Go to Question 13
3 Is the lid sealing on the
tub correctly?
Go to Question 5 Go to Question 4
4 Are the lid actuators
functioning correctly?
Go to Question 5 Check the lid actuators
are assembled correctly
on the slides and yokes.
Check the plugs on the
RFI board and the
terminals on the lid
motors. If the lid
actuators look slow
replace them.
5 Is the water level in the
tub high?
Go to Question 6 Go to Question 8
6 Is the water inlet valve
leaking?
Replace inlet
valve
Go to Question 7
7 Is the DishDrawer
priming correctly?
Go to Question
12
Go to Question 8
8 Is the spray arm split? Replace spray
arm
Go to Question 9