5.2 DEFROST CYCLE
The following table outlines the defrost cycle of an Active Smart refrigerator.
Defrost Cycle of the Active Smart Refrigerator
(With Fin On Tube Evaporator)
Compressor Defrost element Defrost element Compressor Both PC & FC
turns off turns on turns off turns on fans turn on
Defrost time;
Target is 18 minutes
Maximum is 40 minutes
Normal run 2 Minutes 4 minutes 30 sec Back to normal run
Warm up Defrost Drip time Delay
If 40 minutes has elapsed, defros
t
would be aborted if defrost senso
r
has not reached 8°C. If 2 defrosts
are aborted, Fault code 2 is
displayed.