819091D
34
7.9 KEY PRESSES (Products before JANUARY 2009)
To activate any mode, certain combinations of key presses are required.
The key-presses are as follows. Key presses used by the service technician are those shown shaded.
Function Key Presses Action Press Time
Key Silent Mode Menu
On/Off Hold down for 4 seconds
Key & Dispenser Lock Menu + Measured fill
+
On/Off Hold down for 2 seconds
Key Lock Menu + Measured fill
+
On/Off Hold down for 4 seconds
Diagnostic Mode Menu + Up
+
On Hold down for 4 seconds
Forced Defrost Menu + Down
+
On Hold down for 4 seconds
Sabbath Mode Menu + Measured fill +
Down
+ +
On/Off Hold down for 4 seconds
Disable Filter Alarm Menu + Measured fill + Up
+ +
On/Off Hold down for 4 seconds
Show Off Mode Menu + Down + Up
+ +
On/Off Hold down for 4 seconds
Flowmeter Calibration Measured Fill + Down
+
On Hold down for 4 seconds
Filter Reset Measured Fill + Up
+
Reset Hold down for 4 seconds
Force Icemaker
Manual
Measured Fill + Down + Up
+ +
Activates
once
Hold down for 4 seconds
7.10 KEY PRESSES (Products After JANUARY 2009)
Function Key Presses Action Press Time
Key Silent Mode Scroll to Settings
On/Off Press Up or Down keys to
turn on or off.
Dispenser Lock Lock
On/Off Hold down for 2 seconds
Key Lock Lock
On/Off Hold down for 4 seconds
Diagnostic Mode Menu + Up
+
On Hold down for 4 seconds
Forced Defrost Menu + Down
+
On Hold down for 4 seconds
Sabbath Mode Menu + Down + Lock
+ +
On/Off Hold down for 4 seconds
Disable Filter Alarm Menu + Up + Lock
+ +
On/Off Hold down for 4 seconds
Show Off Mode Menu + Down + Up
+ +
On/Off Hold down for 4 seconds
Filter Reset Up + Lock
+
Reset Hold down for 4 seconds
Force Icemaker
Manual
Lock (first) Down + Up
+
Activates
once
Press Lock key first then
down & up keys and
hold all keys for 4 seconds