16.6 ICE/CONDENSATION FORMING
Does frost
pattern on
evaporator indicate
heavy usage?
Is Smart Tool
data
available?
Repair or replace
faulty components
.
Check that drain is
not blocked.
Are the door
gaskets
sealing
correctly?
Explain to customer that
some ice/condensation is
normal in heavy
usage
situations.
Is the product
getting heavy
usage?
No
No
No
No
Yes
Yes Yes
Yes
Yes
Check Flapper
Element
resistance.
Is the
resistance
OK?
Yes
No
Check connections
at module, if Ok
replace controller
Replace Flapper
element.