EasyManua.ls Logo

Fisher & Paykel RF201A - Water Dispensing Pad Replacement

Fisher & Paykel RF201A
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
819091D
53
Step 2
Two locating pins on the base of the front panel
hold the housing at the bottom.
Note: The housing cannot be removed as
wiring looms prevent the housing being
removed.
Step 3
Disconnect the RAST connectors from the module.
Pull the two bottom tabs forward.
Remove the module.
Step 4
Refit in reverse order.
Ensure the wiring is placed and clipped into the
correct position.
Ensure the water hose is in the correct position
prior to clipping the panel into position.
If necessary, replace the water hose between the
top hinge and the dispenser.
12.4.7 Water Dispenser Pad Replacement
Remove the module (refer to Section 0).
To remove the pad, lift the sensor pad upward.
To refit the sensor pad, ensure the retaining clip is as
shown.
Refit in reverse to above procedure.
Locating pins