EasyManua.ls Logo

Fisher 2500R Series

Fisher 2500R Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
D200124X012
Fisher Controls International, Inc. 1977, 1997; All Rights Reserved
Fisher, Fisher-Rosemount, and Managing The Process Better are marks
owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc.
All other marks are the property of their respective owners.
2500
a
n
d 2
50
3 S
erie
s L
evel-Trol
C
ontroller
s a
nd
Transmitters
Contents
Introduction
2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual 2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensor Assembly 2.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Uncrating 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller/Transmitter Orientation 6.
. . . . . . . . . . . . .
Mounting Caged Sensor 6.
. . . . . . . . . . . . . . . . . . . . .
Mounting Cageless Sensor 7.
. . . . . . . . . . . . . . . . . . .
Side-Mounted Sensor 7.
. . . . . . . . . . . . . . . . . . . . . .
Top-Mounted Sensor 8.
. . . . . . . . . . . . . . . . . . . . . . .
Special Installations 8.
. . . . . . . . . . . . . . . . . . . . . . . . .
Temperature-Compensated Displacer 8.
. . . . . . . .
Piezometer Ring 9.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply and Output Pressure Connection 9.
. . . . . . .
Supply Pressure 10.
. . . . . . . . . . . . . . . . . . . . . . . . .
Controller/Transmitter Output Connection 11.
. . .
Prestartup Checks
11.
. . . . . . . . . . . . . . . . . . . . .
Type 2500 Controller or Type 2500T
Transmitter 13.
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type 2500S Controller 13.
. . . . . . . . . . . . . . . . . . . . .
Type 2503 Controller 14.
. . . . . . . . . . . . . . . . . . . . . .
Adjustments 15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Action 15.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Level Adjustment
(Controllers Only) 15.
. . . . . . . . . . . . . . . . . . . . .
Zero Adjustment
(Transmitters Only) 15.
. . . . . . . . . . . . . . . . . . . .
Proportional Band Adjustment
(Except Transmitters and 2503
Series Controllers) 15.
. . . . . . . . . . . . . . . . . . . . .
Specific Gravity Adjustment
(Transmitters Only) 15.
. . . . . . . . . . . . . . . . . . . . .
Calibration
15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Precalibration Requirements 15.
. . . . . . . . . . . . . . . .
Wet Calibration 15.
. . . . . . . . . . . . . . . . . . . . . . . . . .
Dry Calibration 16.
. . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1. 2500 or 2503 Series Level-Trol
Controller/
Transmitter on Caged 249 Series Sensor
2500 OR 2503 SERIES
CONTROLLER/
TRANSMITTER
249 SERIES SENSOR
W3121-3/IL/A
Controller/Transmitter and Torque Tube Arm
Disassembly 16.
. . . . . . . . . . . . . . . . . . . . . . . . . .
Determining the Amount of
Suspended Weight 16.
. . . . . . . . . . . . . . . . . . . .
Calibration Procedure 17.
. . . . . . . . . . . . . . . . . . . . .
Type 2500 Controller and
2500T Transmitter 17.
. . . . . . . . . . . . . . . . . . . . .
Type 2500S and 2503 Controllers 19.
. . . . . . . . . .
Startup
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type 2500 Controller 20.
. . . . . . . . . . . . . . . . . . . . . .
Type 2500T Transmitter 20.
. . . . . . . . . . . . . . . . . . .
Type 2500S Controller 20.
. . . . . . . . . . . . . . . . . . . . .
Type 2503 Controller 20.
. . . . . . . . . . . . . . . . . . . . . .
Instruction Manual
Form 1013
February 1997
Type 2500

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fisher 2500R Series and is the answer not in the manual?

Fisher 2500R Series Specifications

General IconGeneral
Accuracy±1% of span
Repeatability±0.5% of span
Input SignalPneumatic, 3 to 15 psig (0.2 to 1.0 bar)
Output SignalPneumatic, 3 to 15 psig (0.2 to 1.0 bar)
Supply Pressure20 psi (1.4 bar)
MountingSurface
MaterialsAluminum

Summary

Introduction to 2500 Series Controllers

Installation Procedures

Prestartup Checks

ControllerTransmitter Specific Checks

Prestartup verification steps for 2500, 2500T, 2500S, and 2503 models.

Adjustments

Control Action and LevelZero Adjustments

How to adjust control action, level setpoint, and zero point.

Proportional Band and Specific Gravity Adjustments

How to adjust the proportional band and specific gravity settings.

Calibration

ControllerTransmitter Calibration Procedure

Step-by-step calibration instructions for various models.

Startup Procedures

Type 2500 Controller Startup

Step-by-step procedures for bringing the Type 2500 controller online.

Type 2500 T Transmitter Startup

Step-by-step procedures for bringing the Type 2500T transmitter online.

Maintenance and Troubleshooting

Troubleshooting Guide

Guide to diagnosing and resolving common operating faults.

Parts Ordering

Related product manuals